In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?
Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:
What is the occupant load of a 2,500 net square foot assembly occupancy using tables and chairs?
According to the fire code, when compliance is not immediate, inspection reports of code violations must always include a description of the violation and which of the following?
Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.
Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.
A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.
Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.
How long must records related to this decision be maintained by the code official?
The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.
Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?
A code official may allow the occupant load of a building or room to exceed that specified in the building code if additional exit facilities are provided, all other egress requirements are met, and the maximum occupancy does not exceed one occupant per sq. ft. of occupiable floor area.
The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:
All new building construction must have installed an approved water supply for fire protection which provides a minimum of:
Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?
Conditions that may exist and warrant a modification include all of the following except where the:
Pressure tests for organic coating process piping shall be conducted for a minimum of:
An acceptance test for a fire alarm system in a new apartment building should be scheduled after: