Questions 4

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Buy Now
Questions 5

Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:

Options:

A.

at least 4 ft. wide.

B.

built of noncombustible construction.

C.

built of nonferrous, nonsparking metal.

D.

located no closer than 3 ft. to the side of the tank.

Buy Now
Questions 6

What is the occupant load of a 2,500 net square foot assembly occupancy using tables and chairs?

Options:

A.

167

B.

227

C.

357

D.

500

Buy Now
Questions 7

According to the fire code, when compliance is not immediate, inspection reports of code violations must always include a description of the violation and which of the following?

Options:

A.

The reinspection date

B.

The mandatory court date

C.

Recommended corrective action

D.

The potential fines for noncompliance

Buy Now
Questions 8

Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.

Options:

A.

12

B.

18

C.

24

D.

36

Buy Now
Questions 9

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Buy Now
Questions 10

A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.

Options:

A.

1.25

B.

2

C.

4

D.

6.25

Buy Now
Questions 11

Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.

Options:

A.

1/2-hour

B.

1-hour

C.

2-hour

D.

3-hour

Buy Now
Questions 12

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

Options:

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Buy Now
Questions 13

Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.

How long must records related to this decision be maintained by the code official?

Options:

A.

Five years

B.

Three years

C.

Until the building is sold

D.

For as long as the building and the condition exist

Buy Now
Questions 14

The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.

Options:

A.

30

B.

60

C.

90

D.

120

Buy Now
Questions 15

Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.

Options:

A.

30

B.

100

C.

200

D.

220

Buy Now
Questions 16

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

Options:

A.

They become a public record.

B.

They are time-consuming to complete and file.

C.

They may not address all of the code violations which may be encountered.

D.

They may serve as a basis for legal appeal against the code official's actions.

Buy Now
Questions 17

A code official may allow the occupant load of a building or room to exceed that specified in the building code if additional exit facilities are provided, all other egress requirements are met, and the maximum occupancy does not exceed one occupant per sq. ft. of occupiable floor area.

Options:

A.

3

B.

5

C.

7

D.

10

Buy Now
Questions 18

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

Options:

A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Buy Now
Questions 19

All new building construction must have installed an approved water supply for fire protection which provides a minimum of:

Options:

A.

the required fire flow for fire protection.

B.

a static pressure of 40 psi at each hydrant.

C.

a static pressure of 60 psi at each hydrant.

D.

250 gal. per minute at the fire-access outlet.

Buy Now
Questions 20

A local board of appeals may perform all of the following functions except:

Options:

A.

waive requirements of the fire code.

B.

render interpretations of the fire code.

C.

approve alternate materials and types of construction.

D.

adopt rules and regulations for conducting its investigations.

Buy Now
Questions 21

Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

Options:

A.

Group I-2

B.

Group A-1

C.

Office spaces

D.

Libraries in Group E

Buy Now
Questions 22

Conditions that may exist and warrant a modification include all of the following except where the:

Options:

A.

modification does not lessen health, life, and fire safety.

B.

modification requires the use of an alternative building material.

C.

modification is in compliance with the intent and purpose of the code.

D.

special individual reason makes the strict letter of the code impractical.

Buy Now
Questions 23

Hazardous occupancies involved in the manufacturing of organic coatings:

Options:

A.

do not require a fire alarm system.

B.

require only a manual fire alarm system.

C.

require only an automatic fire alarm system.

D.

require both manual and automatic fire alarm systems.

Buy Now
Questions 24

Pressure tests for organic coating process piping shall be conducted for a minimum of:

Options:

A.

30 minutes

B.

45 minutes

C.

1 hour

D.

2 hours

Buy Now
Questions 25

Fire inspectors receiving citizen complaints about a building should first:

Options:

A.

record all pertinent information.

B.

investigate the history of the building.

C.

forward the complaint to the senior inspector.

D.

inform the owner of the building that a complaint has been filed against him.

Buy Now
Questions 26

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:

A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Buy Now
Exam Code: Fire-Inspector-II
Exam Name: 67 - Fire Inspector II Exam