Black Friday Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtick70

NS0-527 NetApp Certified Implementation Engineer - Data Protection Questions and Answers

Questions 4

A customer is running multiple Oracle DBs over NFS. The volumes are replicated using SnapMirror to a secondary site, which also hosts the development and test systems. They want to streamline the creation of test environments on the secondary site so that they will not have to manually use FlexClone to clone multiple volumes for each request.

In this scenario, which tool satisfies these requirements?

Options:

A.

Snap Creator Framework

B.

OnCommand Unified Manager

C.

NetApp Service Level Manager

D.

OnCommand Workflow Automation

Buy Now
Questions 5

Click the Exhibit button.

In an ONTAP environment, an SVM-DR relationship exists between your AFF A220 cluster and your FAS2720 cluster, with identity preserve enabled. You are asked to test thedisaster recovery workflow in an upcoming maintenance window.

Referring to the exhibit, which step should be performed next to test the recovery workflow?

Options:

A.

Delete the SVM-DR relationship.

B.

Pause any ongoing transfers.

C.

Abort any ongoing transfers.

D.

Update any ongoing transfers.

Buy Now
Questions 6

A previous administrator had configured an external backup system to use node-scoped NDMP for backups, but you want to change this system to use SVM-scoped NDMP. How do you make this change in ONTAP?

Options:

A.

Turn off node-scoped NDMP on the SVMs being backed up.

B.

Restart the NDMP service on the cluster.

C.

Restart the NDMP service on the SVMs being backed up.

D.

Turn off node-scoped NDMP on the cluster.

Buy Now
Questions 7

A customer wants a new solution that reaches a near-zero recovery time objective (RTO) and a zero recovery point objective (RPO).

In thisscenario, which NetApp solution satisfies the requirements?

Options:

A.

NDMP

B.

MetroCluster

C.

SnapMirror

D.

SnapVault

Buy Now
Questions 8

You are asked to provide a solution that will allow a client to copy the data stored in a FlexVol volume to a remote tape system for archiving. You are using a cluster-aware backup application to perform this task.

Which three actions are required when you configure this solution for your client? (Choose three.)

Options:

A.

Configure NDMP at the SVM level.

B.

Configure multiple LIFs for SVM-scoped NDMP.

C.

Configure NDMP at the node level.

D.

Create a backup user account on the cluster.

E.

Configure a LIF for node-scoped NDMP.

Buy Now
Questions 9

You want to ensure that you are using compatible hardware and software versions with your MetroCluster installation. Which tool would accomplish this task?

Options:

A.

Hardware Universe

B.

System-Level Diagnostics tool (SLDIAG tool)

C.

OneCollect

D.

Interoperability Matrix Tool

Buy Now
Questions 10

You do not want to impact your ongoing SnapMirror relationship between your primary and secondary site. Which step must be taken prior to creating a FlexClone at the disaster recovery site?

Options:

A.

Cascade the SnapMirror destination volume to another SnapMirror destination.

B.

Create a Snapshot copy of the SnapMirror destination volume.

C.

Cascade the SnapMirror destination volume to another SnapVault destination.

D.

Create a Snapshot copy of the SnapMirror source volume and wait for it to transfer.

Buy Now
Questions 11

Which two statements are correct about configuring a peering connection between clusters? (Choose two.)

Options:

A.

The LIFs should be on the same subnet.

B.

You must use at least one intercluster LIF per node.

C.

You must use one cluster LIF per node per network.

D.

The intercluster LIFs must have full connectivity to each other.

Buy Now
Questions 12

You have deployed a 4-node fabric MetroCluster configuration for cross-site disaster-recovery protection. In this scenario, which two statements are correct for an automatic unplanned switchover (AUSO) operation?

(Choose two.)

Options:

A.

AUSO is triggered in the event of a site-wide controller failure to provide nondisruptive operations.

B.

AUSO is triggered in the event of a complete site-wide failure to provide nondisruptive operations.

C.

AUSO is triggered in the event of a site-wide switch failure to provide nondisruptive operations.

D.

AUSO is enabled by default on a MetroCluster cluster.

Buy Now
Questions 13

You want to determine the amount of cold data that can be tiered from a FabricPool-enabled aggregate.

In thisscenario, which feature satisfies this requirement?

Options:

A.

Inactive Data Reporting

B.

Information Lifecycle Management

C.

Object Store Profiler

D.

Auto Balance

Buy Now
Questions 14

After deploying an ONTAP Select 2 node HA cluster at a remote site, you successfully perform manual takeover and giveback before placing the cluster into production. After the cluster runs in production for a week, you notice that you can no longer perform a manual takeover.

In this scenario, what are two causes of this problem? (Choose two.)

Options:

A.

There is a network disruption between sites.

B.

ONTAP Deploy has been deleted.

C.

The vSphere HA service has failed.

D.

The HA interconnect cables have been removed.

Buy Now
Questions 15

A customer is using SnapMirror to replicate their data to a remote site. They notice that storage efficiency is nor preserved, and the amount of data at the destination is higher than expected.

In this scenario, which configuration in the destination volume would cause this issue?

Options:

A.

Post process deduplication is enabled on the destination.

B.

The volumes are not thin-provisioned onthe destination.

C.

Post process compression is enabled on the destination.

D.

There is an existing FlexClone volume on the destination.

Buy Now
Questions 16

Click the Exhibit button.

An AFF A700 administrator is told that the VMwareenvironment will be upgraded to vSphere 7 and it will continue to use NFSv3 for their datastores.

Referring to the exhibit, which version of SnapCenter Hypervisor Plugin and SnapCenter Server should they use?

Options:

A.

SnapCenter Plug-in 4.2.1 and SnapCenter Server 4.2.1

B.

SnapCenter Plug-in 4.3.1 and SnapCenter Server 4.3.1

C.

SnapCenter Plug-in 4.3 and SnapCenter Server 4.1

D.

SnapCenter Plug-in 4.3 and SnapCenter Server 4.3

Buy Now
Questions 17

You received an alert from OnCommand Unified Manager (OCUM) that a NetApp FlexVol is almost out of space. Which three actions are available to perform from the OCUM events detail Web page?

(Choose three.)

Options:

A.

Acknowledge the event.

B.

Mark the event as "resolved".

C.

Create a job to move the FlexVol.

D.

Increase the capacity of the FlexVol.

E.

Add a note to the event.

Buy Now
Questions 18

You noticed that your SnapVault relationship is healthy but that the destination volume does not have any Snapshot copies.

In this scenario, what should be performed to solve the problem?

Options:

A.

Set up volume destination free space.

B.

Set up volume source free space.

C.

Use the snapvault update command.

D.

Configure a rule with the Snapshot label.

Buy Now
Questions 19

A customer has a MetroCluster solution and wants to automate the disaster-recovery process. The customer wants to control the switchcover between the sites.

Which NetApp tool would satisfy these requirements?

Options:

A.

OnCommand Unified Manager

B.

MetroCluster Tiebreaker

C.

OnCommand System Manager

D.

OnCommand SnapCenter

Buy Now
Questions 20

You want to use SnapCenter to restore an MS SQL database on iSCSILUNs from a previous application- consistent snapshot.

In this scenario, what is required to accomplish this task?

Options:

A.

Confirm multipathing for iSCSI is enabled on the host.

B.

Confirm that the database server is running on the host.

C.

Confirm thatthe database server is not running on the host.

D.

Confirm that the iSCSI service is disabled on the host.

Buy Now
Questions 21

You want to configure peering between two existing ONTAP HA clusters.

In this scenario, which three steps would you perform to accomplish this task? (Choose three.)

Options:

A.

Create a cluster peering relationship.

B.

Create intracluster LIFs.

C.

Create intercluster LIFs.

D.

Create a SVM peeringrelationship.

E.

Create iSCSI LIFs.

Buy Now
Questions 22

Click the Exhibit button.

Your customer wants to protect a volume and replicate it to a secondary volume. The customer has tried to configure this relationship using OnCommand System Manager. Upon reviewing this newly configured relationship, you discover that the configuration does not satisfy the customer’s stated requirements.

Referring to the exhibit, what should you do to ensure that the volume is protected?

Options:

A.

Deletethe relationship and recreate it.

B.

Resynchronize the relationship.

C.

Initialize the relationship.

D.

Change the schedule to hourly.

Buy Now
Questions 23

You recently set up a SnapMirror relationship with a daily update schedule. You want to verify that the updates are being performed daily.

Which two actions inside OnCommand System Manager would you ensure that the SnapMirrortransfers are occurring daily? (Choose two.)

Options:

A.

In the Jobs window, verify that all manual Snapshot copy operations have completed in the past 24 hours.

B.

In the Jobs window, verify that all SnapMirror jobs have completed within the past 24 hours.

C.

Inthe Relationships window, verify that the relationship state was broken in the past 24 hours.

D.

In the Relationships window, verify that the lag time is less than 24 hours.

Buy Now
Exam Code: NS0-527
Exam Name: NetApp Certified Implementation Engineer - Data Protection
Last Update: Nov 24, 2024
Questions: 156
NS0-527 pdf

NS0-527 PDF

$25.5  $84.99
NS0-527 Engine

NS0-527 Testing Engine

$30  $99.99
NS0-527 PDF + Engine

NS0-527 PDF + Testing Engine

$40.5  $134.99