New Year Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtick70

5V0-62.22 VMware Workspace ONE 21.X UEM Troubleshooting Specialist Questions and Answers

Questions 4

A number of enrolled devices have not checked in with VMware Workspace ONE UEM for several days. When the administrator attempted to push a profile to the devices the devices did not check in to receive the profile.

Which component should be focused on when troubleshooting this device connectivity issue to VMware Workspace ONE UEM?

Options:

A.

UEM Console

B.

UAG

C.

API

D.

Device Services

Buy Now
Questions 5

An organization administrator started utilizing VMware Workspace ONE UEM to configure emails clients on managed Android, OS, and Windows devices. Windows and Android users can access their email inboxes. iOS device users are able to check in, but their email inbox fails to load:

What is the most likely cause of this issue?

Options:

A.

The organization's Apple sToken expired.

B.

The profile that configures the email client is misconfigured.

C.

The organization group that assigns the email client is misconfigured.

D.

The organization's Apple Push Notification certificate expired.

Buy Now
Questions 6

An organization wants to use VMware Workspace ONE UEM to deploy a new internal application to Android devices. An organization administrator uploads the application installation file into UEM and assigns the application via a smart group Users report the application installation begins on their devices but fails after about ten minutes

What is the most likely cause of this issue?

Options:

A.

The application installation file is corrupted.

B.

The application installation file extension is not supported.

C.

The organization's Google integration is misconfigured.

D.

The application assignment is misconfigured.

Buy Now
Questions 7

After deploying an iOS profile, there are several devices that are not showing successful installation. Upon reviewing the troubleshooting logs, the administrator notices that the device has responded with NotNow.

Which action should the administrator take to resolve this status?

Options:

A.

Check the AWCM server logs to ensure that the device is connected to Cloud Messaging.

B.

Send several push notifications to the device in order to allow processing of profiles

C.

Contact the user, and ensure the iOS device is unlocked and powered on.

D.

Re-push the profile to the device since the hang up is on the Workspace ONE UEM side

Buy Now
Questions 8

An organization administrator recently integrated their shared SaaS VMware Workspace ONE UEM and their internal Microsoft Active Directory

Most users report they can enroll their Android and iOS devices using their user account from the organization's internal Microsoft Active Directory, but a few users report they cannot The organization administrator find the user accounts of the users unable to enroll failed to synchronize to VMware Workspace ONE UEM

What is the most likely cause of this issue?

Options:

A.

The organization administrator misconfigured the bind user credentials.

B.

The organization administrator misconfigured the Bind Authentication Type.

C.

The users that failed to synchronize have two or more globally unique identifiers.

D.

The users that failed to synchronize are missing a phone number in Active Directory

Buy Now
Questions 9

The VMware Workspace ONE UEM administrator in an organization found that the Certificate Authority integration test connection failed recently I his organization uses on-premises Microsoft ADCS CA as their certificate authority, which resides on an internal-only Windows server. The VMware Workspace ONE UEM console resides in the cloud.

Why did this certificate authority integration test connection fail?

Options:

A.

Entrust PKI is disabled under the Certificate Authorities settings.

B.

Symantec MPKI is disabled under the Certificate Authorities settings.

C.

Fetching the root certificate from CA failed.

D.

Credential in UEM is incorrect.

Buy Now
Questions 10

An Active Directory administrator added a number of new user accounts to a group that is synced in VMware Workspace ONE UEM, but after several days, the new directory accounts have not synchronized into the VMware Workspace ONE UEM console.

After checking the Directory Services configuration in the VMware Workspace ONE UEM console, the administrator confirmed Auto Sync and Auto Merge are enabled for the group Which two log files would be used to troubleshoot issues related to this Directory synchronizations? (Choose two.)

Options:

A.

DirectorySyncServiceLogFile.log

B.

WebLogFile.log

C.

CloudConnector.log

D.

AWServices log

E.

DeviceServicesLog. log

Buy Now
Questions 11

An administrator has started to integrate Workspace ONE UEM with test connection and is unable to move forward.

Which situation could cause this test connection failure?

Options:

A.

The provided Workspace ONE Access Username is incorrect

B.

The provided Workspace ONE UEM API key is incorrect

C.

The provided Workspace ONE UEM Username is incorrect.

D.

The provided Workspace ONE Access API key is incorrect.

Buy Now
Questions 12

After introducing an additional AWCM server (for a total of two), enrollments have periodically started to fail. While testing, the administrator notices that when https//awcm.awmdm com;2001/awcm/statistics?awcmsessionid—12345 is accessed, the user is consistently bounced between both AWCM nodes

Which misconfiguration would be causing this behavior?

Options:

A.

AWCM offloading is not property configured.

B.

AWCM Persistence is not correctly configured.

C.

WCM secure channel certificate is not installed.

D.

AWCM ports are not opened to the new AWCM server.

Buy Now
Questions 13

Which VMware Tunnel utility can help troubleshooting by gathering all the necessary component log files that may be required during the process?

Options:

A.

tunnel_snap

B.

tunnel_vi

C.

tunnela_udrt

D.

tunnel_nano

Buy Now
Questions 14

An organization has successfully used VMware Workspace ONE UEM to deploy a managed, public application to Android, iOS, and Windows devices in the same OG for the last year.

The Windows and Android users can still install this application The iOS device users, however, report that they can see and install other applications in the VMware Workspace ONE Catalog, but suddenly they are unable to see this application in the VMware Workspace ONE Catalog.

What is the most likely cause of this issue?

Options:

A.

The application assignment via a smart group was misconfigured.

B.

The application assignment via the enrollment type was misconfigured.

C.

The organization's Apple Push Notification certificate expired.

D.

The organization's Apple sToken expired.

Buy Now
Questions 15

The following error is seen on the AirWatch Cloud Connector (ACC) logging:

Which connectivity should be investigated to restore ACC functionality?

Options:

A.

From ACC to AWCM

B.

From the Active Directory Server to the ACC

C.

From AWCM to the Active Directory Server

D.

From the ACC to the Active Directory server

Buy Now
Questions 16

A newly-hired administrator has opened a ticket with the Internal IT Helpdesk, stating that they can login but do not have access to the Scheduler settings located at Groups & Settings > All Settings > Admin > Scheduler A colleague performing the same role can see and access this entitlement.

What are two reasons that the newly-hired admin is having this difficulty? (Choose two.)

Options:

A.

The newly-hired administrator needs to accept the EULA before sensitive configuration settings are visible by this account.

B.

The newly-hired administrator has the correct roles assigned but has not selected the applicable role in the console access dropdown to view this configuration

C.

The newly hired administrator did not enter in the restricted action pin to enter the Scheduler settings.

D.

The newly-hired administrator needs to navigate to Accounts > Administrators > Roles and assign themselves the correct level of access to access the Scheduler setting.

E.

The newly-hired administrator has the incorrect roles assigned or was not yet provided the correct roles to view this configuration.

Buy Now
Questions 17

Upon deploying a fresh Unified Access Gateway via the OVF template, the administrator sees the following:

Refer to the exhibit.

The administrator would like to avoid running the VAMI command and reconfiguring the network Which other option to remediate this error message is possible?

Options:

A.

Reboot the UAG, press F10, and in the setparams, enter rw init=/bin/bash.

B.

Login to the UAG with the root account, and manually modify the Ifconfig.

C.

Redeploy the UAG to ensure that all of the guest property configurations have been configured correctly

D.

Power off the UAG, and reconfigure the quest properties to ensure that the information is correct.

Buy Now
Questions 18

A VMware Workspace ONE administrator is managing a fleet of console

Which step would assist in troubleshooting this problem?

Options:

A.

Network traffic tools to capture Android traffic

B.

xCode to extract the device debug log

C.

Android SDK and do a tcpdump

D.

Workspace ONE UEM Console Request Debug Log

Buy Now
Exam Code: 5V0-62.22
Exam Name: VMware Workspace ONE 21.X UEM Troubleshooting Specialist
Last Update: Dec 22, 2024
Questions: 60
5V0-62.22 pdf

5V0-62.22 PDF

$25.5  $84.99
5V0-62.22 Engine

5V0-62.22 Testing Engine

$30  $99.99
5V0-62.22 PDF + Engine

5V0-62.22 PDF + Testing Engine

$40.5  $134.99