New Year Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: cramtick70

5V0-21.21 VMware HCI Master Specialist Questions and Answers

Questions 4

During a vSAN design workshop, an architect collected these customer requirements:

* Leverage vSAN storage policies with Erasure Coding.

* Enable Deduplication and Compression.

* Use the minimum number of hosts in the cluster.

* Maintain full storage policy compliance when two nodes are down.

Which vSAN cluster design meets the customer’s requirements?

Options:

A.

Five nodes All-Flash vSAN cluster

B.

Six nodes All-Flash vSAN cluster

C.

Six nodes Hybrid vSAN cluster

D.

Five nodes Hybrid vSAN cluster

Buy Now
Questions 5

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.

Which three prerequisites must be satisfied before completing the task? (Choose three.)

Options:

A.

Create an encryption storage policy

B.

Enable Data-In-Transit encryption first

C.

Enable that the virtual machines are powered on

D.

Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E.

Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F.

Establish a trusted connection with the KMS

Buy Now
Questions 6

An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the data. Both vSAN clusters are managed by the same vCenter server.

What should the administrator configure?

Options:

A.

NFS volumes on vSAN

B.

iSCSI targets on vSAN

C.

HCI Mesh on vSAN

D.

vVOLs on vSAN

Buy Now
Questions 7

Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.

Which two causes explain this behavior? (Choose two.)

Options:

A.

The cluster DRS threshold has been set to Aggressive.

B.

There is a vSAN node failure.

C.

The vSAN Resync throttling is enabled.

D.

The object repair timer value has been increased.

E.

The vSAN policy protection level has changed from FTT=0 to FTT=1.

Buy Now
Questions 8

An architect is designing a vSAN cluster.

Which storage controller option will yield optimal performance?

Options:

A.

Hugh queue depth

B.

Set caching to 50% read on the controller

C.

Enable battery write-back caching

D.

RAID 0

Buy Now
Questions 9

During a design workshop for a stretched vSAN cluster, the requirement that some of the VMs be configured with no-mirror between sites was discussed.

Which three recommendations should the architect provide to address an event of a network partition between two sites? (Choose three.)

Options:

A.

Host isolation response must exclude the VMs required

B.

The default gateway must be used as the only isolation address

C.

One of isolation addresses should reside in the site 1 data center

D.

VMware vSphere DRS rules to force the VMs to run where the data resides

E.

One isolation address reachable only from the witness appliance in both sites

F.

One of isolation addresses should reside in the site 2 data center

Buy Now
Questions 10

A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.

During the discovery phase, the consultant found the following information about the existing environment:

* The vCenter Server is currently version 7.0.

* The vSAN Cluster has the following configuration:

- vSAN version: 7.0

- Number of vSAN nodes: 6

- Encryption: enabled

- Deduplication and Compression: enabled

- Fault Domains: 1

- vSAN Capacity Utilization: 60%

* Each vSAN node has the following configuration:

- ESXi version: VMware vSphere 7.0

- CPU: 2 processors, 20 cores

- RAM: 1024GB RAM.

- Disk: 2 Cache SSDs and 6 Capacity SSDs

- Network: 4 x 10GbE

* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.

Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

Options:

A.

Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).

B.

Disable vSAN Encryption before starting the upgrade process.

C.

Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).

D.

Set VMware Distributed Resource Scheduling (DRS) to partially automated.

E.

Upgrade to VMware vCenter Server 7.0 U1.

F.

Choose the Allow reduced redundancy option.

Buy Now
Questions 11

After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).

Which step should be taken to resolve this issue?

Options:

A.

Configure vmk0 with IP address on the same range as that of vmk1.

B.

Tag the vmk0 for vSAN traffic.

C.

Configure vmk1 with IP address on the different network than that of vmk0.

D.

Tag the vmk1 for Witness traffic.

Buy Now
Questions 12

An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the “Full-data migration” option.

What will happen after this action is taken?

Options:

A.

The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.

B.

The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.

C.

The host will enter in maintenance mode and only data with no redundancy will remain accessible.

D.

The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.

Buy Now
Questions 13

An architect is designing a vSAN cluster where the hosts have more than 512 GB of memory.

Which two boot devices are recommended for these hosts? (Choose two.)

Options:

A.

USB

B.

PMEM

C.

SD

D.

Disk Device

E.

SATADOM

Buy Now
Questions 14

An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.

Which version of Kerberos must be selected if the NFS version is v4.1?

Options:

A.

krb5i

B.

krb4

C.

krb5

D.

krb5p

Buy Now
Questions 15

An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.

What is the minimum number of vSAN nodes required?

Options:

A.

6

B.

4

C.

5

D.

8

Buy Now
Questions 16

A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.

The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:

* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding

* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring

* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring

* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring

During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:

* Preferred Site - Preferred Site workloads should run on DC1 hosts.

* Secondary Site - Secondary Site workloads should run on DC2 hosts.

Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

Options:

A.

Change the Site Disaster Tolerance setting in Policy 3 to be “Dual Site Mirroring”.

B.

Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.

C.

Change the Site Disaster Tolerance setting in Policy 4 to be “None - Keep Data on Preferred”.

D.

Change the FTT setting in Policy 3 to be “Erasure Coding”.

E.

Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.

Buy Now
Questions 17

An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.

The company also has the following:

* An iSCSI array of 300TB. which runs at 76% of its capacity

* A NAS system of 200TB, which runs at 10% of its capacity

* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity

The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.

Which storage option will work for this use case?

Options:

A.

Create an HCI Mesh using the first cluster’s datastore.

B.

Obtain additional free capacity from the existing NAS storage.

C.

Obtain additional free capacity from the existing FC storage.

D.

Create an HCI Mesh using the second cluster’s datastore.

Buy Now
Questions 18

An architect is currently working with a customer to transform their existing ESXi hosts to vSAN nodes. The customer expressed the following requirements.

• First phase will transform 50% of the hosts to a hybrid vSAN nodes.

• Second phase will transform the remaining 50% hosts to an All-Flash vSAN nodes.

The following constraint exists:

• Each host has a 4-port x 1 GbE network interface.

Which two recommendations should the architect make to align with the customer's requirements? (Choose two.)

Options:

A.

Hybrid vSAN clusters can have shared 1 GbE network adapters.

B.

All-Flash vSAN clusters must have dedicated 10 GbE network adapters.

C.

Hybrid vSAN clusters must have dedicated 1 GbE network adapters.

D.

All-Flash vSAN clusters can have shared 10 GbE network adapters.

E.

Hybrid vSAN clusters must have dedicated 10 GbE network adapters.

Buy Now
Questions 19

An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.

Which action should the administrator take so the migration is successful?

Options:

A.

Disable vSAN Deduplication and Compression

B.

Reconfigure vCenter HA Admission control

C.

Enable vCenter Single Sign-On Enhanced Linked Mode

D.

Make sure that Witness traffic is on the management NIC.

Buy Now
Exam Code: 5V0-21.21
Exam Name: VMware HCI Master Specialist
Last Update: Dec 27, 2024
Questions: 66
5V0-21.21 pdf

5V0-21.21 PDF

$25.5  $84.99
5V0-21.21 Engine

5V0-21.21 Testing Engine

$30  $99.99
5V0-21.21 PDF + Engine

5V0-21.21 PDF + Testing Engine

$40.5  $134.99